Single-Use Automatic Biopsy Needle for Precise Sampling

One hand usage.

22 mm penetration depth.

Double firing trigger in proximal and distal positions.

Atraumatic and Echogenic needle tip design for optimum ultrasound visibility

Light weight handle

Adjustable sample notch: 10mm/20mm

Centimeter marked cannula

Optionally: “Co-axial needles” are available

It is a disposable automatic biopsy device used to take samples of soft tissues and organs. Echogenic marker placed at the distal tip and needle with depth marking.

14G, 16G and 18G

Sterilized by ETO, shelf life 5 years.

    Specifications

    Available Sizes 14G, 16G, 18G
    Available lengths 9 cm, 11cm, 15 cm, and 20 cm
    Available in two throw lengths 10 mm and 20 mm
    An extra-thin wall is available
    Supplied sterile in peel-open packages
    Intended for one-time use only

    Production Description

    The automatic biopsy needle is a medical device designed for efficient and precise tissue sample collection for diagnostic purposes. Unlike manual biopsy needles, automatic versions incorporate a spring-loaded mechanism that rapidly advances the inner stylet and outer cutting cannula to capture a tissue core.

    The automatic Biopsy Needle is designed to provide medical professionals with a safe and effective way to perform percutaneous biopsies of various organs including kidney, liver, lung, breast, thyroid, prostate, pancreas, body surface and more.

    The Automatic Biopsy Needle is available in a range of essential gauges: 14G, 16G, and 18G, catering to diverse tissue acquisition needs

    For enhanced accuracy and reduced patient discomfort, the automatic biopsy needle is designed for seamless integration with a coaxial introducer needle. The coaxial needle is always one size larger than the biopsy needle (e.g., a 13G coaxial needle for a 14G biopsy needle), facilitating multiple samples through a single skin puncture and minimizing tissue trauma.

    Key Advantages:

    • Precise and Consistent Sampling: The automatic firing mechanism ensures a rapid and complete cutting action, yielding consistently high-quality, intact tissue cores for accurate diagnosis.

    • Enhanced User Control and Confidence: The ergonomic design and intuitive operation allow for single-handed use, providing greater control during the procedure and reducing operator fatigue.

    • Minimized Patient Discomfort: The swift, automated firing reduces procedure time and patient movement, contributing to a more comfortable experience. When used with the coaxial needle, it further reduces the number of skin punctures.

    • Versatile Sizing: The range of available gauges (14G, 16G, 18G) provides flexibility to address different tissue densities and lesion types.

    • Coaxial Capability: The ability to be used with a coaxial introducer needle allows for multiple passes through a single entry point, reducing patient discomfort and the risk of complications associated with repeated punctures.

     

    Application

    The Automatic Biopsy Needle is ideal for a wide range of diagnostic biopsy procedures, including but not limited to:

    • Breast Biopsies

    • Liver Biopsies

    • Kidney Biopsies

    • Lung/Pleural Biopsies

    • Prostate Biopsies

    • Lymph Node Biopsies

    • Soft Tissue Mass Biopsies